Man Machine Interface service program
MMI


Purposes
Functional possibilities
Download the service program MMI



 


 

Purposes

The program is designed to work on PC. The instruments included are intended for setting and configuration of the relay and also for uploading visualization and storing of the recorded events and disturbances. The program also offers and the possibility for remote monitoring of the main operational parameters (analogue and binary) of the relay.

System requirements:
PC Pentium MMX 233MHz or better;
Properly working operational system MS Windows 9x/NT/2000/XP;
Display mode 800 x 600 pixels or better;
Standard RS 232 interface.



Functional possibilities


Configuration

 

Receiving, reviewing and saving (to the PC) the configuration parameters of the devices;
Creating of the new configurations and changing of the received configurations;
Send and store the configuration to the devices;
Printing of the configuration parameters.


Relay protection settings

 

Receiving, reviewing and saving (to the PC) the relay protection settings of the devices;
Creating of the new relay protection settings and changing of the received settings;
Send and store the relay protection settings to the devices;
Printing of the relay protection settings.

Event Recorder

 

Receiving, reviewing and saving to the PC of the events from the devices
Remote clearing of the events in the device’s Event Recorder
Printing of the events.

Disturbance recorder

  Receiving of the oscillographic information, reviewing in graphical mode and saving to the PC
Remote clearing of the oscillographic information in the device’s Disturbance Recorder
Printing of the oscillographic information.

Measurement of the current data from the device

 

Binary inputs position
Binary outputs position
LED indication & Blinkers lighting
Visualizing of the values from the current inputs (measured and calculated values for each relay protection function)
Visualizing of the values from the voltage inputs
Visualizing of the values for active and reactive power
Undervoltage relays pick-up or drop-off
Directional relays pick-up or drop-off
The primary values of the currents for Data acquisition and control part
The primary values of the voltages for Data acquisition and control part
The primary values of the active and reactive power for Data acquisition and control part
Indication of the energy meters
Frequency
The Limits overreached
Indication of the periodic energies - Daily, Monthly, Yearly values

Binary outputs and blinkers control

 

Download the service program MMI

Multifunctional relay protection, automation and remote control – RFI 401

  MMI – ver. 09 / 16.01.2005 - /ZIP 406KB/
MMI – ver. 05 / 13.06.2003 - /ZIP 343KB/

Multifunctional overcurrent protection – RFI 421

  MMI – ver. 04 / 15.02.2005 íà àíãëèéñêè åçèê - /ZIP 345KB/
MMI – ver. 03 / 21.04.2004 - /ZIP 348KB/
MMI – ver. 01 / 23.12.2004 - /ZIP 390KB/

Two or three winds transformer differential protection – RTI 402/3

  MMI – ver. 4.1 / 27.05.2004 - /ZIP 331KB/
MMI – ver. 3.1 / 20.11.2002 - /ZIP 315KB/

Multifunctional motor protection, automation and remote control – RMI 401

  MMI – ver. 2.0 / 07.03.2001 íà àíãëèéñêè åçèê - /ZIP 225KB/

Multifunctional overcurrent protection for powerful motor – RMI 421

  MMI – ver. 3.7 / 07.03.2004 - /ZIP 348KB/

Under & Over voltage protection – REA 421

  MMI – ver. 3.8 / 10.04.2004 - /ZIP 363KB/

Distance protection, automation and remote control – RLI 401

  MMI – ver. 5.2 / 27.05.2004 - /ZIP 690KB/
MMI – ver. 5.1 / 12.02.2004 - /ZIP 348KB/

Directional four stages earth fault protection – RED 421

  MMI – ver. 03 / 21.04.2004 - /ZIP 348KB/

Frequency relay - RFA 401

  MMI – ver. 1.1 / 02.07.2004 íà àíãëèéñêè åçèê - /ZIP 317KB/